Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Practice tests / ICC Fire Inspector II (67)
ICC · Last updated November 2026

Fire Inspector II (67): free practice test

ICC's senior fire inspector certification, for inspectors who evaluate egress, fire protection, occupancy classification and regulated materials in the field and witness acceptance tests. General fire safety provisions are 36% of the exam, occupancies and regulated materials 22% each, and inspection administration 20%. You must hold a current Fire Inspector I certification first.

Watch the free 4:22 video lesson: the key ICC Fire Inspector II (67) concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free ICC Fire Inspector II (67) study dashboard: flashcards, notes and your Readiness Score, no signup →

About the ICC Fire Inspector II (67) exam

ICC's senior fire inspector certification, for inspectors who evaluate egress, fire protection, occupancy classification and regulated materials in the field and witness acceptance tests. General fire safety provisions are 36% of the exam, occupancies and regulated materials 22% each, and inspection administration 20%. You must hold a current Fire Inspector I certification first.

What's on the exam

ICC Fire Inspector II (67)
General Inspection Administration
7 key facts
Means of Egress, Emergency Access and Emergency Planning
7 key facts
Construction Types, Exposures and Fire Flow Testing
7 key facts
Fire Protection Systems: Readiness, Inspection and Plan Comparison
7 key facts
Occupancy Classification and Number of Occupants
7 key facts
Occupancy Inspections
7 key facts
Industrial and Commercial Processes
7 key facts
Storage, Handling and Interior Finishes
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the ICC Fire Inspector II (67) exam

  • 50 questions in 120 minutes is 2.4 minutes each. Occupant load (8%) and flow test questions take longest, so answer the quick administration items first.
  • Occupancies and regulated materials are 44% of this exam. Tab IBC Table 1004.5, the IBC Chapter 3 occupancy descriptions, IFC Table 5003.1.1(1) and Table 5003.8.3.2.
  • Read every exception and table footnote. Sprinkler allowances often exclude a group, and hazardous material increases sit in the notes under the table.
  • Administration is 20% across ten 2% tasks. Read IFC Chapter 1 closely, because permits, appeals and records are easy marks if you know where they are.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the Fire Protection Formulas & Values Sheet.

Take the test first

What's in the premium ICC Fire Inspector II (67) prep

Premium ICC Fire Inspector II (67) prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 50 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 8 topics

Your step-by-step study path

  1. 1
    General Inspection Administration8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Notes free with an account
  2. 2
    Means of Egress, Emergency Access and Emergency Planning8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  3. 3
    Construction Types, Exposures and Fire Flow Testing8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  4. 4
    Fire Protection Systems: Readiness, Inspection and Plan Comparison8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  5. 5
    Occupancy Classification and Number of Occupants7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  6. 6
    Occupancy Inspections7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  7. 7
    Industrial and Commercial Processes7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  8. 8
    Storage, Handling and Interior Finishes7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  9. Final step: 6 full mock exams50 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete ICC Fire Inspector II (67) study notes for “General Inspection Administration”

Our first full set of comprehensive notes, about 12 minutes of reading: Permits · Inquiries, research and communication · Reports, records and complaints · Enforcement, appeals and legal proceedings · Scheduling, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A promoter applies to erect a 20 ft by 30 ft tent with sidewalls on all sides for a three-day festival. Under the IFC, what is the permit status?
Answer: An operational permit is required because the tent exceeds 400 sq ft. 20 x 30 = 600 sq ft, above the 400 sq ft trigger in IFC Section 105 and Chapter 31. The 700 sq ft allowance applies only to tents open on all sides with 12 ft of clearance, so sidewalls remove it. Check the open-sides exception before applying the area limit.
2. An owner cited for a missing sprinkler system says the retrofit is too costly and asks the board of appeals to waive it. What should your written response on the appeal process explain?
Answer: The board may rule on interpretation or equivalency but cannot waive code requirements. Under IFC Section 111, an appeal must claim that the code was interpreted incorrectly, does not fully apply, or that an equivalent method of protection is proposed. The board has no authority to waive code requirements, so cost alone is not a ground. Keep correspondence to those grounds and the filing process.
3. While researching a fire alarm question, you find that the IFC and an NFPA standard it references give different requirements for the same feature. Which requirement governs?
Answer: The IFC requirement. IFC Section 102 says that where the code and a referenced standard conflict, the code's provisions apply. The most restrictive rule is a different one, used when sections of the code itself specify different materials or methods. Cite the code first in your report.
4. A conference center classified Group A-3 is sprinklered throughout. You measure a 30-ft dead-end corridor that is 6 ft wide. Applying the IBC and IFC egress provisions for new construction, what is your finding?
Answer: Violation, as the 50-ft sprinkler exception does not cover Group A. The base limit is 20 ft. The 50-ft allowance for sprinklered buildings lists Groups B, E, F, I-1, M, R-1, R-2, S and U, not Group A. The no-limit exception needs a length under 2.5 times the least width, here 15 ft, so 30 ft still fails.
5. An arena event is expected to draw 2,600 people. Under the IFC, what is the minimum number of trained crowd managers?
Answer: 11. IFC Section 403 requires crowd managers where more than 1,000 people gather, at not less than one for each 250 persons or portion thereof. 2,600 / 250 = 10.4, which rounds up to 11. Rounding down leaves the last 100 people uncovered.
6. During a flow test, you read 16 psi on the pitot gauge at a 2.5-in. smooth outlet with a discharge coefficient of 0.90. About what flow is the hydrant discharging?
Answer: About 671 gpm. Q = 29.83 x Cd x d squared x square root of P = 29.83 x 0.90 x 6.25 x 4, or about 671 gpm. Leaving out the coefficient gives 746 gpm, and forgetting to square the diameter gives 268 gpm. Taking the square root of the pressure is the step most often missed.
7. An older building has 2-hour concrete-masonry exterior bearing walls, with interior walls, floors and roof of unrated dimension-lumber framing. Which IBC construction type best describes it?
Answer: Type IIIB. Type III has noncombustible exterior walls with any permitted material inside. IIIB requires no rating on interior elements, while IIIA needs 1 hour. Type VB would allow combustible exterior walls, and Type IV-HT needs heavy timber sizes rather than dimension lumber.
8. At 8 a.m., a manager shuts down the sprinkler system in an occupied warehouse after a pipe break and plans the repair for tomorrow. What must happen under the IFC?
Answer: Notify the fire department and code official at once; evacuate or post a fire watch as required. IFC Section 901.7 requires immediate notification of the fire department and the fire code official when a required system is out of service. Where the official requires it, the building is evacuated or an approved fire watch is provided until the system is restored. The 10-hour figure comes from NFPA 25's impairment program and does not delay notification.
9. At an acceptance test, you find the contractor moved a sprinkler main and added two sprinklers, neither shown on the approved shop drawings. How should you proceed?
Answer: Require amended construction documents to be submitted and approved. IFC Section 105 requires work to follow the approved construction documents, and changes made during construction are resubmitted as an amended set. A passing test proves the pipe holds pressure, not that the revised layout meets the design. Amendments are allowed, so removal is not automatically required.
10. A retail store has 12,000 sq ft gross of sales floor and 3,000 sq ft gross of stock room. Using the 2021 code occupant load factors, what is the total design occupant load?
Answer: 210. Mercantile uses 60 gross sq ft per person: 12,000 / 60 = 200. Storage and stock areas use 300 gross sq ft per person: 3,000 / 300 = 10. The total is 210. Applying the mercantile factor to the stock room overstates the load at 250.
11. A licensed home provides 24-hour personal care to 12 residents, excluding staff. All residents can evacuate without physical help. What is the IBC occupancy classification?
Answer: Group R-4, Condition 1. Group R-4 covers residential care for more than 5 but not more than 16 persons, excluding staff; Condition 1 means residents can evacuate without physical assistance. Above 16 persons it becomes Group I-1, and 5 or fewer can be Group R-3. Group I-2 is for medical care of people incapable of self-preservation.
12. A nightclub is sprinklered throughout, has no emergency voice/alarm system and has an occupant load of 600. What minimum clear width must its main exit provide?
Answer: 60 in.. In Group A with more than 300 occupants, the main exit must serve at least half the occupant load, here 300 people. Without an emergency voice/alarm system, the factor for doors is 0.2 in. per occupant: 300 x 0.2 = 60 in. The 0.15 factor needs both sprinklers and a voice system.
13. At a motor fuel-dispensing facility with exterior dispensers, the labeled emergency disconnect switch is inside the store, 110 ft from the nearest dispenser. What is your finding?
Answer: Violation, as the switch must be within 100 ft of the dispensers. IFC Section 2303.2 places the switch within 100 ft of, but not less than 20 ft from, the exterior dispensers. The 20-ft minimum keeps the switch reachable during a fire at the island, and the 100-ft maximum keeps it close enough to use. Being labeled or indoors does not cure the distance.
14. A Group F-1 shop sprinklered throughout uses both control areas allowed on the third story. Each stores Class II combustible liquid outside cabinets. What is the maximum total quantity on that story?
Answer: 240 gal. The base quantity for Class II is 120 gal, and sprinklers add 100%, giving 240 gal. Table 5003.8.3.2 limits the third story to 50% per control area, so 120 gal each. Two control areas give 240 gal in total; stopping at one control area gives 120 gal.
15. In a six-story nonsprinklered Group B office building, a paneling test report shows a flame spread index of 60 and a smoke-developed index of 300. Can it be used on the walls of an interior exit stairway?
Answer: No, as the panel is Class B and the stairway requires Class A. A flame spread index of 26 to 75 with a smoke-developed index of 0 to 450 is Class B. IBC Table 803.13 requires Class A in interior exit stairways of nonsprinklered Group B buildings; the Class B allowance applies only under three stories. The smoke limit is 450 for all classes.

Get the full ICC Fire Inspector II (67) prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

ICC Fire Inspector II (67) exam FAQ

How many questions are on the ICC Fire Inspector II (67) exam?

50 multiple-choice questions, four options each, with a time limit of 2 hours. Format: open book. icc's catalog lists the international building code and international fire code (both also provided as free digital references during the exam) and ifsta fire inspection and code enforcement. bound, copyrighted books are allowed; study guides and practice questions are not. a second version of the exam uses a different edition of the ibc and ifc: pick the code edition when you buy the exam.

What is the passing score for ICC Fire Inspector II (67)?

Scaled score of 75 (ICC national certification standard); ICC does not publish the raw percentage, which varies by exam form.

How much does the ICC Fire Inspector II (67) exam cost?

US$320 (ICC store price; ICC members pay less). Fees and reference editions change, so confirm on nfpa.org before you apply.

Which languages is the ICC Fire Inspector II (67) exam offered in?

English. ICC's catalog does not list other languages; confirm with ICC.

Where do I take the ICC Fire Inspector II (67) exam?

ICC PRONTO: in person at a test center or online with remote proctoring.

Is this ICC Fire Inspector II (67) practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full ICC Fire Inspector II (67) prep is Premium at $147 a month for this exam.

What's in the premium ICC Fire Inspector II (67) prep?

3,000 practice questions organized topic by topic (General Inspection Administration: 375; Means of Egress, Emergency Access and Emergency Planning: 375; Construction Types, Exposures and Fire Flow Testing: 375; Fire Protection Systems: Readiness, Inspection and Plan Comparison: 375; Occupancy Classification and Number of Occupants: 375; Occupancy Inspections: 375; Industrial and Commercial Processes: 375; Storage, Handling and Interior Finishes: 375), 6 full-length timed mock exams of 50 questions, 800 flashcards and 60 comprehensive key notes split across all 8 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in November 2026. NFPA changes formats and fees, so confirm with International Code Council (ICC) before you book. CFPSExamPrep is not affiliated with NFPA or Prometric.

Start the free test