Certified Hazard Recognition Specialist (CHRS): free practice test

NFPA's awareness-level credential for applying NFPA 101, Life Safety Code (2021) to find conditions that endanger building occupants. The exam weights are General Requirements 25%, Means of Egress 22%, Protection 20%, Building Services 16% and Building Rehabilitation 17%. Candidates have 12 months from approval to pass.

Watch the free 4:33 video lesson: the key CHRS concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free CHRS study dashboard: flashcards, notes and your Readiness Score, no signup →

About the CHRS exam

NFPA's awareness-level credential for applying NFPA 101, Life Safety Code (2021) to find conditions that endanger building occupants. The exam weights are General Requirements 25%, Means of Egress 22%, Protection 20%, Building Services 16% and Building Rehabilitation 17%. Candidates have 12 months from approval to pass.

What's on the exam

CHRS
Definitions and General Requirements
7 key facts
Occupancy Classification and Hazard of Contents
7 key facts
Means of Egress Components and Capacity
6 key facts
Exit Number, Arrangement, Discharge and Marking
7 key facts
Protection: Barriers, Openings and Interior Finish
7 key facts
Building Services and Fire Protection Equipment
7 key facts
Special Structures and High-Rise Buildings
6 key facts
Building Rehabilitation
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the CHRS exam

  • Tab the current edition by chapter before exam day. You may not add tabs or write in the book during the exam, and the Handbook is not allowed.
  • Building Rehabilitation is 17% from one chapter, so Chapter 43's work categories are high-value study time.
  • When a question names an occupancy, check the occupancy chapter as well as Chapters 7 and 8. The blueprint includes related requirements in Chapters 12 to 42.
  • Three hours for 75 questions gives you about 2 minutes 24 seconds each, so you have time to confirm answers in the book.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the Fire Protection Formulas & Values Sheet.

Take the test first

What's in the premium CHRS prep

Premium CHRS prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 75 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 8 topics

Your step-by-step study path

  1. 1
    Definitions and General Requirements8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Notes free with an account
  2. 2
    Occupancy Classification and Hazard of Contents8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  3. 3
    Means of Egress Components and Capacity8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  4. 4
    Exit Number, Arrangement, Discharge and Marking8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  5. 5
    Protection: Barriers, Openings and Interior Finish7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  6. 6
    Building Services and Fire Protection Equipment7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  7. 7
    Special Structures and High-Rise Buildings7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  8. 8
    Building Rehabilitation7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  9. Final step: 6 full mock exams75 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete CHRS study notes for “Definitions and General Requirements”

Our first full set of comprehensive notes, about 12 minutes of reading: NFPA official definitions · General definitions that drive egress questions · Compliance options and fundamentals · Drills and emergency action plans, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. An office manager holds a required egress drill at 10 a.m. on the first Monday of each quarter, always using the same stair. Which finding best applies under NFPA 101, Section 4.7?
Answer: Drills must vary in timing and conditions, so this routine is inadequate. Section 4.7 requires drills at expected and unexpected times and under varying conditions, to simulate what can happen in a real emergency. Holding them at the same time by the same route trains a habit that may fail when that stair is unavailable. Reaching an exit is necessary, but it does not make the drill program adequate.
2. An occupant leaves a third-floor office, walks along a corridor, enters a 1-hour enclosed stair and leaves it through a door to an open court that leads to the street. Which portion is the exit?
Answer: The enclosed stair. An exit is the portion of a means of egress separated from other spaces by construction, giving a protected way to the exit discharge. Here that is the enclosed stair. The corridor and office door are exit access, and the court between the stair and the street is exit discharge.
3. An outpatient surgery center treats five patients at a time under general anesthesia, with no one staying overnight. What is its occupancy classification?
Answer: Ambulatory health care occupancy. Ambulatory health care covers four or more patients made incapable of self-preservation by treatment or anesthesia, on less than a 24-hour basis. Health care occupancy requires care on a 24-hour basis. Without the incapacitating treatment, the clinic would likely be a business occupancy.
4. A two-story building has retail on the ground floor and a 120-person banquet hall above. No fire barrier separates them, and the occupancies are treated as mixed. Which requirements apply?
Answer: The most restrictive requirements of both occupancies throughout the building. Section 6.1.14 treats mixed occupancies by applying the most restrictive life safety requirements of the occupancies involved throughout the building. Applying each set of rules only within its own area requires the separated occupancy option with the required rated fire barriers. Floor area does not decide which set of rules prevails.
5. A door on a level exit path in a business occupancy has a clear width of 36 in. Using Table 7.3.3.1, what egress capacity does it provide?
Answer: 180 persons. Level components and ramps use 0.2 in. per person in most occupancies, so 36 / 0.2 = 180 persons. Using the stair factor of 0.3 in. per person gives the wrong 120. Check whether the component is a stair or a level path before dividing.
6. A new meeting room has an occupant load of 60 and two side-hinged doors that both swing into the room. What does NFPA 101 require?
Answer: Both doors must swing in the direction of egress travel. Side-hinged or pivoted-swinging door leaves must swing in the direction of egress travel where they serve a room or area with an occupant load of 50 or more (7.2.1.4). The rule applies to each door serving the room, not just one of them. Latching and panic hardware do not change the swing requirement.
7. A story in a building protected throughout by an approved, supervised automatic sprinkler system has a maximum overall diagonal of 180 ft. What is the minimum separation between two required exits?
Answer: 60 ft. Section 7.5.1.3 requires separation of at least half the maximum overall diagonal, reduced to one-third in buildings protected throughout by an approved, supervised sprinkler system. One-third of 180 ft is 60 ft. Using the half-diagonal rule would give 90 ft, which applies when the sprinkler reduction is not available.
8. An office building with four required exit stairs plans to discharge three of them through a sprinklered ground-floor lobby with an unobstructed path outdoors. What does NFPA 101, Section 7.7 allow?
Answer: Only two stairs, and no more than 50% of the required exit capacity, may do so. Section 7.7.2 limits discharge through areas on the level of exit discharge to 50% of the required number of exits and 50% of the required capacity, and only with specific protection. Four required stairs means two at most. A sprinklered lobby meets one condition but does not lift the 50% cap.
9. A new building is protected throughout by an approved automatic sprinkler system. The occupancy chapter requires Class B corridor wall finish and adds no further limits. The proposed finish has a flame spread index of 150 and a smoke developed index of 300. Is it acceptable?
Answer: Yes, Section 10.2.8.1 permits Class C where Class B is otherwise required. A flame spread index of 76 to 200 with smoke developed up to 450 is Class C. Section 10.2.8.1 lets Class C be used where Class B is required when an approved sprinkler system is installed. The smoke limit is 450 for all three classes, and occupancy chapters can tighten the reduction, so check them.
10. Records for a building's fire door assemblies show the last documented inspection was 26 months ago. What does NFPA 101 require?
Answer: Inspection and testing at least annually, so this is overdue. Fire door assemblies must be inspected and tested at least annually in accordance with NFPA 80, with written records kept. A 26-month gap misses that interval. Inspection is routine; it is not triggered only by repairs.
11. A new office has a storage room of combustible supplies that the occupancy chapter treats as an ordinary hazardous area. Which protection meets the general rule of Section 8.7.1?
Answer: A 1-hour fire barrier without windows, or sprinklers with smoke partitions. Section 8.7.1 allows a 1-hour fire barrier without windows or an automatic extinguishing system. Where sprinklers are the chosen option, the area is separated by smoke partitions with self-closing doors. A smoke partition alone or extinguishers do not provide the required protection.
12. A required fire alarm system is taken out of service for repair and the contractor expects about 6 hours of downtime. What must happen?
Answer: Notify the AHJ, and evacuate or provide an approved fire watch until restored. Under NFPA 101 Chapter 9, when a required fire alarm system is out of service for more than 4 hours in a 24-hour period, the AHJ must be notified and the building evacuated or an approved fire watch provided. The 10-hour figure is the threshold for sprinkler systems. Battery tests do not replace the required action.
13. A building's highest occupiable floor is 70 ft above the lowest level of fire department vehicle access. A normally unoccupied mechanical penthouse above it reaches 85 ft. Does the high-rise definition apply?
Answer: No, the floor of the highest occupiable story is not over 75 ft. A high-rise building has an occupiable story floor more than 75 ft above the lowest level of fire department vehicle access. The measurement is to the floor of the highest occupiable story, so an unoccupied penthouse does not count. Roof height and story count are not the test.
14. Within one tenant's space, a contractor removes a partition, adds a new door and reconfigures the rooms. No exit or shared corridor is affected, and the rest of the floor stays in use. What work category is this under Chapter 43?
Answer: Modification. Modification includes reconfiguring space and adding, relocating or eliminating doors. It becomes reconstruction only if the reconfiguration affects an exit or a corridor shared by more than one occupant space, or the work area cannot be occupied. Renovation does not reconfigure space, and repair is patching or painting.
15. A vacant retail store is being converted to a nursing home. Under Section 43.7, what must the converted space meet?
Answer: The occupancy chapter for new health care occupancies. A change to a higher hazard category, a lower hazard category number, must comply with the occupancy chapter for new construction for the occupancy created. A nursing home sits in a higher hazard category than a store. The existing chapter applies only when the change is within the same or to a lower hazard category.

Get the full CHRS prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

CHRS exam FAQ

How many questions are on the CHRS exam?

75 multiple-choice questions, with a time limit of 3 hours maximum. Format: open book: the official printed nfpa 101, life safety code, in the edition named by the exam body, is the only reference allowed. the life safety code handbook may be used to study but not in the exam. permanent tabs only, added before the exam; personal calculators are not permitted, and a calculator is on screen.

What is the passing score for CHRS?

Not published by NFPA; results are reported as pass or fail only, with a diagnostic report by content area.

How much does the CHRS exam cost?

US$305 initial application and exam; US$249 retest; US$225 recertification every 3 years. Fees and reference editions change, so confirm on nfpa.org before you apply.

Which languages is the CHRS exam offered in?

English only.

Where do I take the CHRS exam?

Prometric (proctored computer-based exam at in-person test centers worldwide).

Is this CHRS practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full CHRS prep is Premium at $147 a month for this exam.

What's in the premium CHRS prep?

3,000 practice questions organized topic by topic (Definitions and General Requirements: 375; Occupancy Classification and Hazard of Contents: 375; Means of Egress Components and Capacity: 375; Exit Number, Arrangement, Discharge and Marking: 375; Protection: Barriers, Openings and Interior Finish: 375; Building Services and Fire Protection Equipment: 375; Special Structures and High-Rise Buildings: 375; Building Rehabilitation: 375), 6 full-length timed mock exams of 75 questions, 800 flashcards and 60 comprehensive key notes split across all 8 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in November 2026. NFPA changes formats and fees, so confirm with National Fire Protection Association (NFPA) before you book. CFPSExamPrep is not affiliated with NFPA or Prometric.

Start the free test