Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Practice tests / NFPA CEI
NFPA · Last updated November 2026

Certified Electrical Inspector (CEI): free practice test

NFPA's certification for electrical inspectors, combining an open-book exam on the NEC with a practicum of 8 inspections. Construction Documents is 32% of the exam, Field Inspection 31%, Communication 20% and Administration 17%. This prep covers only the written exam. You have 12 months from application approval to pass the exam and complete the practicum.

Watch the free 4:28 video lesson: the key NFPA CEI concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free NFPA CEI study dashboard: flashcards, notes and your Readiness Score, no signup →

About the NFPA CEI exam

NFPA's certification for electrical inspectors, combining an open-book exam on the NEC with a practicum of 8 inspections. Construction Documents is 32% of the exam, Field Inspection 31%, Communication 20% and Administration 17%. This prep covers only the written exam. You have 12 months from application approval to pass the exam and complete the practicum.

What's on the exam

NFPA CEI
Administration: Authority, Permits, Licensing and Legal Proceedings
8 key facts
Communication: Reports, Notices and Code Interpretation
6 key facts
Construction Documents: Load Calculations and System Capacity
8 key facts
Construction Documents: Conductors, Overcurrent, Equipment Ratings and Occupancy
8 key facts
Field Inspection: Grounding and Bonding
7 key facts
Field Inspection: Wiring Methods, Boxes and Working Space
7 key facts
Field Inspection: Testing, GFCI and AFCI Protection, and Hazards
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the NFPA CEI exam

  • 80 questions in 3 hours is 2 minutes 15 seconds each, enough to look up every table, so tab your NEC before test day. Only permanent adhesive tabs are allowed, and you cannot mark the book during the exam.
  • Construction Documents is the largest domain at 32%. Practice Article 220 load calculations with the 2023 numbering: 220.41 for the dwelling unit load, Table 220.45 for lighting demand and Table 220.47 for receptacle demand.
  • Use the edition of the NEC named by the exam body even if your jurisdiction enforces another edition. A newer NEC edition moved load calculations to Article 120, so a newer codebook gives wrong section numbers for this exam.
  • Administration and Communication together are 37%, and they are judgment questions. Choose the answer that follows the adopted code, the jurisdiction's written procedure and due process, and that cites a specific section.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the Fire Protection Formulas & Values Sheet.

Take the test first

What's in the premium NFPA CEI prep

Premium NFPA CEI prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 80 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    Administration: Authority, Permits, Licensing and Legal Proceedings9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Communication: Reports, Notices and Code Interpretation9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Construction Documents: Load Calculations and System Capacity9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Construction Documents: Conductors, Overcurrent, Equipment Ratings and Occupancy9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Field Inspection: Grounding and Bonding8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Field Inspection: Wiring Methods, Boxes and Working Space8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    Field Inspection: Testing, GFCI and AFCI Protection, and Hazards8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams80 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete NFPA CEI study notes for “Administration: Authority, Permits, Licensing and Legal Proceedings”

Our first full set of comprehensive notes, about 12 minutes of reading: Where authority comes from · Reading the Code as an enforcer · Permits and plan review · Legal proceedings and licensing, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A permit covers a 200 A service upgrade. At the inspection the service is compliant, but you find a new 60 A feeder to a detached garage that is not on the permit or the approved documents. What is the best action?
Answer: Approve the service and hold the feeder until the permit is amended. An inspection approves the work within the permit's scope, so the compliant service can pass while the unpermitted feeder is held until the permit is amended under the jurisdiction's procedure. Approving it anyway bypasses plan review and fees. Revoking the permit is out of proportion to a correctable scope problem.
2. An existing industrial building cannot meet a specific NEC requirement during a renovation. The engineer submits an alternative with documented, ongoing safeguards. Under Article 90, how may the authority having jurisdiction respond?
Answer: Allow it if equivalent safety is established and maintained. Section 90.4 lets the AHJ waive specific requirements or permit alternative methods where equivalent objectives can be achieved by establishing and maintaining effective safety. The engineer's seal supports the request but does not decide it. Keep a written record of the basis for the decision.
3. A plan reviewer drafts a correction stating that a long branch circuit violates the NEC because voltage drop exceeds the 3% figure in an informational note. The jurisdiction has no local voltage-drop rule. What should happen to the correction?
Answer: Remove it as a violation; the note may be raised only as advice. Under 90.5, informational notes are explanatory and not enforceable as requirements of the Code. A correction must rest on mandatory text or a local amendment. The reviewer can mention voltage drop as a recommendation, but cannot hold the job for it.
4. Which correction notice entry best meets the blueprint standard of accurate, clear and concise documentation?
Answer: "Panel P-1, basement: no bonding jumper on metal water pipe (250.104(A)). Install; reinspect.". A usable notice states the location, the condition found, the code section and the action needed. Vague entries such as a general Article 250 reference cannot be corrected or defended on appeal. Personal opinion has no place in an inspection record.
5. Your jurisdiction enforces an earlier NEC edition with local amendments. A contractor installs work that meets a rule in a newer NEC edition but not the adopted rule, and says the newer edition must control. How should you respond in writing?
Answer: Apply the adopted NEC as amended, unless the AHJ accepts the rule as an alternative. The legally adopted edition and its amendments are what the jurisdiction enforces, and NFPA does not decide local adoption. A newer rule can be used only through the AHJ's alternative-method authority. Your written response should also explain the appeal route.
6. A 2,400 sq ft dwelling is reviewed under the optional calculation in 220.82. Loads: general lighting at 3 VA/sq ft, two small-appliance circuits, one laundry circuit, a 12 kW range, a 5 kW dryer, a 4.5 kW water heater and 6 kVA of air conditioning, with no electric heat. What is the calculated service load on a 120/240 V system?
Answer: 105 A. General loads total 7,200 + 3,000 + 1,500 + 12,000 + 5,000 + 4,500 = 33,200 VA. Take 10,000 VA at 100% plus 23,200 VA at 40% (9,280 VA) for 19,280 VA, then add the air conditioning at 100% to reach 25,280 VA; divided by 240 V, that is 105 A. Leaving out the air conditioning gives 80 A.
7. An office tenant fit-out shows 120 general-use receptacle outlets, each counted at 180 VA. What receptacle load should the reviewer carry to the feeder calculation under the non-dwelling demand factors?
Answer: 15,800 VA. Connected load is 120 x 180 VA = 21,600 VA. Table 220.47 allows the first 10 kVA at 100% and the remainder at 50%: 10,000 + 5,800 = 15,800 VA. Taking 50% of the whole load gives the tempting 10,800 VA.
8. A feeder serves 48 A of continuous load and 10 A of noncontinuous load. No adjustment or correction factors apply, and the terminals are rated 75 C. What is the smallest copper conductor that satisfies Article 215?
Answer: 4 AWG. Minimum ampacity is 125% of the continuous load plus the noncontinuous load: 60 + 10 = 70 A. In the 75 C column, 6 AWG is only 65 A and 4 AWG is 85 A. The next-size-up rule in 240.4(B) concerns the overcurrent device, so it cannot reduce the 70 A required ampacity.
9. New construction documents show 42 kA available at a panelboard. The main is rated 65 kA and the branch breakers 14 kA. The engineer's note says the main will protect the branch breakers. What should the reviewer require?
Answer: A tested, listed series combination, or fully rated branch breakers. Each device must be rated for the available fault current under 110.9 unless a series rating applies. For new work, 240.86(B) requires a combination tested by the manufacturer and marked as 110.22 requires. Engineered series ratings under 240.86(A) are limited to existing installations.
10. A retail space is converted to a restaurant with a posted occupant load of 140. The building code requires fire-rated construction in this portion of the building. Drawings show Type NM cable concealed above the dining room. What is the correct finding?
Answer: Not compliant: Article 518 applies, and NM is limited to nonrated construction. Article 518 covers assembly occupancies of 100 or more persons and lists restaurants. Section 518.4 allows NM cable only in construction the building code does not require to be fire rated. Occupant load, not former use, sets the rule, so check it on every change of occupancy.
11. A service has two parallel sets of 500 kcmil copper per phase. The grounding electrode conductor runs to the building's metal underground water pipe. What is the minimum copper size of that conductor?
Answer: 2/0 AWG. Table 250.66 uses the equivalent area of the parallel conductors: 2 x 500 = 1,000 kcmil, which falls in the over 600 through 1,100 kcmil row and requires 2/0 AWG copper. Sizing from one set gives 1/0. The 6 AWG limit in 250.66(A) applies only to the portion going solely to rod, pipe or plate electrodes.
12. A 200 A feeder has its ungrounded copper conductors increased from 3/0 AWG to 250 kcmil for voltage drop. The table-sized equipment grounding conductor is 6 AWG copper. What minimum wire-type equipment grounding conductor is required?
Answer: 4 AWG. Section 250.122(B) requires a proportional increase. The ratio is 250,000 / 167,800 = 1.49, and 26,240 cmil x 1.49 is about 39,100 cmil, which exceeds 6 AWG; the next size is 4 AWG at 41,740 cmil. Leaving it at 6 AWG is the common inspection miss.
13. A 480Y/277 V switchboard has exposed live parts on its front when opened, facing a concrete wall across the aisle. There are no exposed live parts on the wall side. What minimum working-space depth does Table 110.26(A)(1) require?
Answer: 3 ft 6 in.. At 277 V to ground, the 151 to 600 V row applies. Concrete counts as grounded, so this is Condition 2, which requires 3 ft 6 in. Condition 1 would be 3 ft and Condition 3, with live parts on both sides, 4 ft. The 6 ft 6 in. figure is the minimum headroom.
14. A square metal box will contain ten 12 AWG insulated conductors, three 12 AWG equipment grounding conductors, internal cable clamps and one receptacle on a single yoke. Which is the smallest box from Table 314.16(A) that complies?
Answer: 4-11/16 in. x 2-1/8 in. (42.0 cu in.). Count 10 conductors, 1 allowance for up to four equipment grounding conductors, 1 for the clamps and 2 for the yoke: 14 x 2.25 cu in. = 31.5 cu in. The 30.3 cu in. box is short by 1.2 cu in., so 42.0 cu in. is the first listed size that works. Counting each grounding conductor separately overstates the fill.
15. A new solidly grounded 480Y/277 V service has a 1,000 A disconnect. At final inspection, the ground-fault protection equipment appears correctly installed. What must you also verify under 230.95?
Answer: That a written record of the on-site test is available to the AHJ. Section 230.95 requires performance testing when the system is first installed on site, with a written record available to the AHJ. A factory test does not prove field wiring and sensor polarity. The maximum setting is 1,200 A, and 3,000 A is only the one-second limit on the time-current curve.

Get the full NFPA CEI prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

NFPA CEI exam FAQ

How many questions are on the NFPA CEI exam?

80 multiple-choice questions, single response, with a time limit of 3 hours. Format: open book: only the official printed nfpa 70, national electrical code, in the edition named by the exam body. the nec handbook is not allowed in the exam. a practicum of 8 inspections is separate: this prep covers only the written exam.

What is the passing score for NFPA CEI?

Not published by NFPA: results are reported as pass or fail with a diagnostic report, and the score is not disclosed. A practicum must also be approved. Aim for 75% or higher in practice.

How much does the NFPA CEI exam cost?

US$499 initial application and exam; US$249 retest; US$225 recertification every 3 years. Fees and reference editions change, so confirm on nfpa.org before you apply.

Which languages is the NFPA CEI exam offered in?

English only.

Where do I take the NFPA CEI exam?

Prometric (in-person computer-based test centers worldwide).

Is this NFPA CEI practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full NFPA CEI prep is Premium at $147 a month for this exam.

What's in the premium NFPA CEI prep?

3,000 practice questions organized topic by topic (Administration: Authority, Permits, Licensing and Legal Proceedings: 450; Communication: Reports, Notices and Code Interpretation: 425; Construction Documents: Load Calculations and System Capacity: 425; Construction Documents: Conductors, Overcurrent, Equipment Ratings and Occupancy: 425; Field Inspection: Grounding and Bonding: 425; Field Inspection: Wiring Methods, Boxes and Working Space: 425; Field Inspection: Testing, GFCI and AFCI Protection, and Hazards: 425), 6 full-length timed mock exams of 80 questions, 800 flashcards and 60 comprehensive key notes split across all 7 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in November 2026. NFPA changes formats and fees, so confirm with National Fire Protection Association (NFPA) before you book. CFPSExamPrep is not affiliated with NFPA or Prometric.

Start the free test