Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
NFPA · Last updated November 2026

Certified First Responder Inspector (CFRI): free practice test

NFPA's entry-level fire inspection credential, based on the job performance requirements in Chapter 6 of NFPA 1030. The exam weights are Field Inspection 60%, Administrative Duties 38% and Legal 2%. Candidates also complete a separate 10-activity practicum, which this prep does not cover.

Watch the free 4:20 video lesson: the key CFRI concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free CFRI study dashboard: flashcards, notes and your Readiness Score, no signup →

About the CFRI exam

NFPA's entry-level fire inspection credential, based on the job performance requirements in Chapter 6 of NFPA 1030. The exam weights are Field Inspection 60%, Administrative Duties 38% and Legal 2%. Candidates also complete a separate 10-activity practicum, which this prep does not cover.

What's on the exam

CFRI
Administrative Duties: Reports, Permits and Complaints
8 key facts
Legal Proceedings and Testimony
6 key facts
Occupancy Classification and Occupant Load
8 key facts
Means of Egress Maintenance
7 key facts
Fixed Fire Suppression System Readiness
7 key facts
Fire Alarm Systems and Portable Extinguishers
7 key facts
Emergency Access and Fire Growth Hazards
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the CFRI exam

  • Field Inspection is 60% of the exam, so spend most of your time on egress, occupant load, system readiness and hazards.
  • Most questions ask what a first responder inspector should do, so expect the best answer to be identify, document and report according to AHJ policy.
  • Tab your printed codes before exam day with permanent tabs. You cannot add tabs or write in them during the exam.
  • NFPA 25 here is the current edition. Check intervals in that edition, because the WBITM exam on this site uses a different edition and some differ.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the Fire Protection Formulas & Values Sheet.

Take the test first

What's in the premium CFRI prep

Premium CFRI prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 75 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    Administrative Duties: Reports, Permits and Complaints9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Legal Proceedings and Testimony9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Occupancy Classification and Occupant Load9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Means of Egress Maintenance9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Fixed Fire Suppression System Readiness8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Fire Alarm Systems and Portable Extinguishers8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    Emergency Access and Fire Growth Hazards8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams75 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete CFRI study notes for “Administrative Duties: Reports, Permits and Complaints”

Our first full set of comprehensive notes, about 12 minutes of reading: Writing correspondence and reports · Identifying the applicable code · Recognizing permits · Complaints and hazards, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. You find pallets blocking an exit access door in a business occupancy. Your jurisdiction has adopted NFPA 101. Which report entry best meets the NFPA 1030 requirement to reference the applicable code?
Answer: NFPA 101, adopted edition, 7.1.10: keep means of egress free of obstructions. The job performance requirement calls for the applicable document, edition and section. The correct entry gives all three. An entry saying 'latest edition' is wrong because the adopted edition is what applies, and a general statement gives the owner nothing to look up.
2. During a routine inspection of a warehouse, you see a contractor torch-cutting a steel beam. No hot work permit is on site, and your AHJ requires one. What is your responsibility at the CFRI level?
Answer: Tell the person in charge a permit is required and notify fire prevention staff. NFPA 1030 asks this level to recognize the need for a permit and communicate it to the owner or representative and to fire prevention staff under AHJ policy. Issuing the permit is not part of this duty, and a fire watch does not replace the permit. Recognize, communicate, follow policy.
3. A tenant phones to say the building's fire alarm panel has been beeping for two weeks. You are assigned the complaint. What must happen to meet the NFPA 1030 complaint requirement?
Answer: Record the complaint details and forward your findings to the AHJ per policy. The requirement is that complaint information is recorded and the findings are forwarded to the AHJ under its policy. Referring the caller elsewhere leaves no record or findings. A persistent signal may mean an impaired alarm, so one report is enough to act on.
4. During a performance with about 300 patrons present, you find a required exit door chained shut. Which action best fits your duty to act on a life safety hazard?
Answer: Have the chain removed at once, notify your supervisor and document it. A locked required exit in an occupied assembly space is an immediate life hazard, so it is corrected on the spot and handled under AHJ policy. A correction period suits non-urgent items. Other exits having enough capacity does not excuse a locked required exit.
5. At an administrative hearing, the owner's attorney asks if you believe the owner intentionally blocked an exit. You saw the blocked door and spoke only with a clerk. What is the best response?
Answer: State what you observed and say you cannot speak to the owner's intent. NFPA 1030 expects information presented factually and a professional demeanor, which includes separating fact from opinion. You did not observe intent, so guessing damages your credibility. A clerk's statement about the owner is hearsay at best and does not prove intent.
6. A converted mansion rents sleeping rooms to 14 transient guests. There is no personal care and there are no cooking facilities in the rooms. How does NFPA 101 classify this single-use occupancy?
Answer: Lodging or rooming house. NFPA 101 treats sleeping accommodations for 16 or fewer people, without personal care or individual cooking, as a lodging or rooming house. A hotel has sleeping accommodations for more than 16 people. Board and care would require personal care services.
7. A 6,000 ft² gross fitness room with exercise equipment has a posted occupant load of 300, and no AHJ-approved increase is on file. You count 240 people. Using the NFPA 101 factor of 50 ft² gross per person, what do you conclude?
Answer: The load is 120, so both the sign and the count exceed it. 6,000 ÷ 50 = 120 people. A posted number has no value unless it is backed by the calculation or an approved increase. Dividing by 15 gives 400, which is the factor for exercise rooms without equipment. Report the discrepancy and act under AHJ policy.
8. An existing assembly room with an occupant load of 180 has a required exit door fitted with an ordinary lever latch. What is the correct finding under NFPA 101?
Answer: Deficient: latched doors serving 100 or more need panic or fire exit hardware. In assembly occupancies, a latch or lock on a door in a required means of egress from an area with 100 or more occupants is allowed only if it is panic or fire exit hardware. An exit sign does nothing for door operation under crowd pressure. Remember the 100-occupant trigger.
9. Records for manually tested battery emergency lights show a 90-minute test each January and no other tests in the past year. What do you report under NFPA 101?
Answer: Deficient: 30-second functional tests are also required monthly. Manually tested units need a functional test at 30-day intervals for at least 30 seconds, and an annual test for at least 1.5 hours. The January test meets only the annual part. Check the records for both frequencies, unless the units are approved self-testing devices.
10. In a store being repainted, you see a sprinkler with paint on its heat-responsive element. Paint is not a factory finish on this sprinkler. Under NFPA 25, what must happen?
Answer: The sprinkler must be replaced because it cannot stay in service. NFPA 25 requires replacement of sprinklers with paint other than that applied by the manufacturer, because paint can delay operation or affect the spray pattern. Solvent cleaning can damage the element and is not an accepted repair. Replace, then check that painters protect the others properly.
11. Main drain records show last year's 72 psi static and 62 psi residual, and this year's 71 psi static and 54 psi residual. What should you conclude under NFPA 25?
Answer: Residual fell more than 10%, so the cause must be identified. Residual dropped 8 psi from 62 psi, which is 12.9%. NFPA 25 requires the cause of a reduction of more than 10% in full-flow pressure to be identified and corrected if necessary. Static pressure alone says little, because a partly closed valve can leave it almost unchanged.
12. A fire alarm control unit shows a supervisory signal for a sprinkler control valve on the second floor. What does this most directly tell you?
Answer: The valve may not be fully open, so its position must be verified. A supervisory signal reports an abnormal condition in a monitored suppression system, such as a control valve moved off normal. Waterflow would be an alarm signal, and a power loss would be a trouble signal. Confirm the valve position, because a closed valve leaves the area unprotected.
13. During a field inspection, the gauge needle on a stored-pressure dry chemical extinguisher is in the undercharged zone. What is the right action?
Answer: Report it as not operational so it is recharged or replaced. A gauge out of the operable range means the extinguisher may not discharge properly, so it is a readiness deficiency to be reported under AHJ policy. Tapping or shaking restores no pressure. Delaying action to the annual service leaves a defective unit in place for months.
14. A hedge has grown to within 12 in. of a private fire hydrant at an existing site. What is the correct finding under NFPA 1?
Answer: Deficient: 36 in. of clear space is needed around the hydrant. NFPA 1 calls for a 36 in. clear space around the circumference of a hydrant unless the AHJ requires or approves otherwise. Being able to see the hydrant is not enough, since firefighters must be able to connect and turn the wrench. Clearance applies all the way around.
15. A small nightclub has covered its stage walls with foam plastic acoustic panels, and no fire test documentation is available. What should you do under NFPA 101?
Answer: Report the foam as not permitted unless fire testing qualifies it. NFPA 101 does not allow foamed plastic as interior wall or ceiling finish unless it qualifies through specific fire testing. A flame spread class alone does not qualify it, and sprinklers do not waive the rule. Foam finish causes very rapid fire growth, so document it and act under AHJ policy.

Get the full CFRI prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

CFRI exam FAQ

How many questions are on the CFRI exam?

75 multiple-choice questions according to NFPA's CFRI web page (the 2026 Program Overview says 73; confirm with NFPA), with a time limit of 3 hours. Format: open book: official printed nfpa 1, nfpa 13, nfpa 25, nfpa 72, nfpa 101 and the ifsta fire inspection and code enforcement manual. code handbooks are not allowed in the exam. permanent tabs only; calculator on screen. this prep covers only the written exam, not the practicum.

What is the passing score for CFRI?

Not published by NFPA; results are reported as pass or fail only. A 10-activity practicum must also be approved.

How much does the CFRI exam cost?

US$499 initial application and exam. Retest and recertification fees are not listed on the CFRI page; confirm with NFPA. Fees and reference editions change, so confirm on nfpa.org before you apply.

Which languages is the CFRI exam offered in?

English only.

Where do I take the CFRI exam?

Prometric (proctored computer-based exam at in-person test centers worldwide).

Is this CFRI practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full CFRI prep is Premium at $147 a month for this exam.

What's in the premium CFRI prep?

3,000 practice questions organized topic by topic (Administrative Duties: Reports, Permits and Complaints: 450; Legal Proceedings and Testimony: 425; Occupancy Classification and Occupant Load: 425; Means of Egress Maintenance: 425; Fixed Fire Suppression System Readiness: 425; Fire Alarm Systems and Portable Extinguishers: 425; Emergency Access and Fire Growth Hazards: 425), 6 full-length timed mock exams of 75 questions, 800 flashcards and 60 comprehensive key notes split across all 7 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in November 2026. NFPA changes formats and fees, so confirm with National Fire Protection Association (NFPA) before you book. CFPSExamPrep is not affiliated with NFPA or Prometric.

Start the free test