NFPA's certification for electricians and technicians exposed to electrical hazards in hands-on work. It is an open-book exam on the edition of NFPA 70E named by the exam body, with Electrical Hazard Risk Assessment at 40% and Work Practices, Electrically Safe Work Condition and Precautionary Techniques at 20% each. Candidates need 40 hours of electrical safety training in the last 3 years plus an apprenticeship, instruction-and-experience or NETA Level III or IV route.

Watch the free 4:31 video lesson: the key NFPA CESW concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free NFPA CESW study dashboard: flashcards, notes and your Readiness Score, no signup →

About the NFPA CESW exam

NFPA's certification for electricians and technicians exposed to electrical hazards in hands-on work. It is an open-book exam on the edition of NFPA 70E named by the exam body, with Electrical Hazard Risk Assessment at 40% and Work Practices, Electrically Safe Work Condition and Precautionary Techniques at 20% each. Candidates need 40 hours of electrical safety training in the last 3 years plus an apprenticeship, instruction-and-experience or NETA Level III or IV route.

What's on the exam

NFPA CESW
Electrical Safety Work Practices and Qualified Persons
7 key facts
Hazard Recognition, Risk Control and Emergency Response
7 key facts
Establishing an Electrically Safe Work Condition
7 key facts
Lockout/Tagout Program and Temporary Grounding
7 key facts
Energized Work, Test Instruments and Portable Equipment
8 key facts
Shock and Arc Flash Risk Assessment
7 key facts
PPE Selection, Care and Other Protective Equipment
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the NFPA CESW exam

  • Bring the edition of NFPA 70E currently listed by the exam body, not a different one. In that edition, energized work is in 110.4, the electrical safety program in 110.5, training in 110.6 and the safe-condition steps in 120.5.
  • Risk assessment is 40% of the exam. Tab Table 130.4(E)(a), Table 130.5(C), Table 130.5(G) and the Table 130.7(C)(15) group so you can reach them in seconds.
  • 110 questions in 3 hours is about 98 seconds each. Answer the definitions and sequence questions quickly and save time for the table lookups.
  • The CESW blueprint still uses some older terms, such as prohibited approach boundary and hazard/risk category. The 2021 standard no longer uses them, so read those as questions about the current boundaries and PPE categories.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the Fire Protection Formulas & Values Sheet.

Take the test first

What's in the premium NFPA CESW prep

Premium NFPA CESW prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 110 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    Electrical Safety Work Practices and Qualified Persons9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Hazard Recognition, Risk Control and Emergency Response9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Establishing an Electrically Safe Work Condition9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Lockout/Tagout Program and Temporary Grounding9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Energized Work, Test Instruments and Portable Equipment8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Shock and Arc Flash Risk Assessment8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    PPE Selection, Care and Other Protective Equipment8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams110 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete NFPA CESW study notes for “Electrical Safety Work Practices and Qualified Persons”

Our first full set of comprehensive notes, about 12 minutes of reading: Language of the standard · What makes a person qualified · Nominal voltage and exposed parts · Job planning and the worker's role, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A journeyman has years of documented training and experience on 480 V motor control centers but has never been trained on 15 kV switchgear. A supervisor asks the journeyman to rack a 15 kV breaker because they are a qualified electrician. What does NFPA 70E say?
Answer: They are not qualified for that equipment without specific training. A qualified person has skills and knowledge for the specific equipment and method and has been trained to identify the hazards involved. A person can be qualified for some equipment and unqualified for other equipment. Heavier PPE or an observer does not replace task-specific training.
2. A worker needs a drill in a wet pit where a corded tool would create a shock risk. Which option ranks highest in the hierarchy of risk control?
Answer: Using a battery-powered drill instead. The hierarchy runs elimination, substitution, engineering controls, awareness, administrative controls and PPE. A battery tool substitutes a lower hazard, which ranks above a GFCI (an engineering control), signs (awareness) and gloves (PPE). Always ask whether the hazard can be removed before adding protection.
3. A coworker is frozen in contact with an energized 277 V lighting conductor. You are trained in contact release and the disconnect is 10 ft away. What should you do first?
Answer: Open the disconnect, then call for emergency medical help. Stop the current without becoming a second victim: open the disconnect if it is quickly available, or use a suitably rated insulated tool. Direct contact with the victim can complete the circuit through you. Call for medical help and begin first aid only once the victim is clear of the source.
4. You must isolate a 480 V feeder using a non-load-break disconnect. The downstream motors are running. What must happen before you open the disconnect?
Answer: Interrupt the load with a device rated to do so. The process in 120.5 opens the disconnecting devices only after properly interrupting the load current. A non-load-break device can arc if it is opened under load. Locks and voltage tests come later in the sequence, and grounding comes last where it is needed.
5. You are testing for absence of voltage on a three-phase, three-wire, 480 V circuit with an equipment ground. How many separate readings does the phase-to-phase and phase-to-ground test require at the work location?
Answer: 6. Test A-B, B-C and C-A (three phase-to-phase) and A-G, B-G and C-G (three phase-to-ground), for six readings. Verify the tester on a known source before and after. Three readings miss the phase-to-ground check, which can reveal a backfeed or induced voltage.
6. A lock from yesterday's shift remains on a disconnect. The electrician who applied it has left the site and cannot be reached by phone. What must happen for the lock to be removed?
Answer: Follow the written procedure, try to find the installer, and inform them before they resume. The lockout/tagout procedure in Article 120 must cover removal when the installer is unavailable. The employer must attempt to locate that person before removal and inform them before they resume work, so nobody assumes the equipment is still protected. Verbal permission alone is not a procedure.
7. A worker wants to skip de-energizing a 48 V dc battery-supplied circuit because it is below 50 V. The battery bank has a very large short-circuit capability. What does NFPA 70E require before relying on the under-50-volt allowance?
Answer: Proof that source capacity adds no burn or arc explosion risk. Under 110.4(C), work below 50 V is allowed energized only where the source capacity and any overcurrent protection are considered and there is no increased exposure to electrical burns or arc explosion. High-capacity low-voltage sources can have serious arc hazards. The blueprint's phrase is "consider capacity."
8. A 100 A breaker feeding a machine trips. Without investigating, an operator resets it, and it trips again. What should the operator do next?
Answer: Stop, and have the cause checked before re-energizing. Article 130 prohibits manually re-energizing after automatic operation until it is determined that the equipment and circuit can be safely energized, and it prohibits repetitive reclosing. Only where the design shows the trip was from an overload may the examination be skipped. Upsizing the breaker removes protection.
9. At the start of a job you find the insulation on one test lead is cracked, exposing a strand of copper. The meter still reads correctly on a known source. What is the correct action?
Answer: Stop using the lead until it is repaired and tested, or replaced. Section 110.8 requires test instruments, leads and accessories to be visually inspected before each use, and a defective item must not be used until repaired and tested. A correct reading says nothing about the insulation's ability to protect you. Tape is not a tested repair.
10. A panelboard has exposed 208Y/120 V, three-phase bus. What is the restricted approach boundary for a qualified worker under Table 130.4(E)(a)?
Answer: 1 ft 0 in.. The table uses phase-to-phase nominal voltage. At 208 V the system is in the 151 to 750 V row, with a restricted approach boundary of 1 ft 0 in. Reading 120 V to ground gives "avoid contact," and 3 ft 6 in. is the limited approach boundary for fixed parts.
11. A painter (unqualified) must briefly work inside the limited approach boundary of exposed 480 V parts in a room. Which arrangement does NFPA 70E permit?
Answer: A qualified person advises and continuously escorts the painter. An unqualified person may cross the limited approach boundary only when a qualified person advises them of the hazards and continuously escorts them. They may never cross the restricted approach boundary. A verbal warning without an escort falls short of the rule.
12. Before operating a 480 V disconnect, you notice scorch marks and a burnt smell at the enclosure. The door is closed and latched. How does NFPA 70E treat the likelihood of an arc flash?
Answer: Normal operating condition is not met, so arc flash controls apply. Under 110.4(D), normal operation relies on several conditions, including no evidence of impending failure. Scorching and burning smell are such evidence, so Table 130.5(C) no longer treats the task as unlikely to cause an arc flash. Stop and assess rather than operating the disconnect as usual.
13. Rubber insulating gloves are needed for a 575 V ac system. Which pair is acceptable under NFPA 70E, assuming each has been in service since its last test?
Answer: Class 0 gloves, last electrically tested 5 months ago. Class 00 is limited to 500 V ac, so it cannot be used at 575 V; Class 0 is rated to 1,000 V ac. Gloves in service must be electrically tested at intervals of no more than 6 months, so the 8-month pair is out of date. Add an air test and inspection before each day's use.
14. An incident energy analysis gives 14 cal/cm2 at the working distance. Using Table 130.5(G), which head and face protection is required?
Answer: An arc flash suit hood with an arc rating of at least 14 cal/cm2. For exposures above 12 cal/cm2, Table 130.5(G) requires an arc-rated arc flash suit hood. The face shield and balaclava option applies only up to 12 cal/cm2. The hood's arc rating must be at least equal to the estimated incident energy.
15. A worker wears arc-rated shirt and pants rated above the calculated incident energy, but has a nylon-blend T-shirt underneath. What is the finding under NFPA 70E?
Answer: Not compliant: meltable fibers next to the skin are not allowed. Underlayers next to the skin must not contain meltable fibers such as nylon, polyester, acetate or polypropylene, because they can melt onto the skin even under an arc-rated layer. Use natural-fiber or arc-rated underlayers. Only an incidental amount of elastic is excepted.

Get the full NFPA CESW prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

NFPA CESW exam FAQ

How many questions are on the NFPA CESW exam?

110 multiple-choice questions, single response (100 scored, 10 unscored), with a time limit of 3 hours. Format: open book: only the official printed nfpa 70e, standard for electrical safety in the workplace, in the edition named by the exam body. the nfpa 70e handbook is for preparation only and is not allowed in the exam.

What is the passing score for NFPA CESW?

Not published by NFPA: results are reported as pass or fail with a diagnostic report, and the score is not disclosed. Aim for 75% or higher in practice.

How much does the NFPA CESW exam cost?

US$499 initial application and exam; US$249 retest; US$225 recertification every 3 years. Fees and reference editions change, so confirm on nfpa.org before you apply.

Which languages is the NFPA CESW exam offered in?

English only.

Where do I take the NFPA CESW exam?

Prometric (in-person computer-based test centers worldwide).

Is this NFPA CESW practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full NFPA CESW prep is Premium at $147 a month for this exam.

What's in the premium NFPA CESW prep?

3,000 practice questions organized topic by topic (Electrical Safety Work Practices and Qualified Persons: 450; Hazard Recognition, Risk Control and Emergency Response: 425; Establishing an Electrically Safe Work Condition: 425; Lockout/Tagout Program and Temporary Grounding: 425; Energized Work, Test Instruments and Portable Equipment: 425; Shock and Arc Flash Risk Assessment: 425; PPE Selection, Care and Other Protective Equipment: 425), 6 full-length timed mock exams of 110 questions, 800 flashcards and 60 comprehensive key notes split across all 7 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in November 2026. NFPA changes formats and fees, so confirm with National Fire Protection Association (NFPA) before you book. CFPSExamPrep is not affiliated with NFPA or Prometric.