The exam at a glance

Questions85 questions
Time9.5-hour appointment: 2-minute nondisclosure agreement, 8-minute tutorial, 8.5 hours of exam and a 50-minute scheduled break
Passing scoreNot published by NCEES. Results are reported as pass or fail
FormatClosed book with electronic references: the PE Fire Protection Reference Handbook and, where a question needs them, NFPA 11, 13, 20, 30, 72, 92, 101, 400, 855 and 2001, all supplied on screen. Personal copies are not allowed. Questions use both SI and US customary units. The real exam has multiple-choice questions and alternative item types; this prep uses 4-option single-best-answer questions
Certifying bodyNational Council of Examiners for Engineering and Surveying (NCEES), with approval by your state licensing board
Test providerPearson VUE test centers, computer-based, on one day per year (next test date April 13, 2027). Seats may be reserved up to a year ahead once registered with NCEES and approved by your board

Mind map: the whole exam on one screen

PE Fire Protection
Fire Protection Analysis
Probability along an event tree branchUL 9540A level for unit-to-unit propagationKey zone model assumptionUL 9540A level for gas composition from thermal runaway
Fire Science
Fast t-squared growth coefficientStefan-Boltzmann constantHeat released per kg of oxygen consumedMedium t-squared growth coefficient
Smoke Control Systems
Axisymmetric plume above limiting heightLimiting flame heightFailure where an exhaust inlet draws air from under the layerPlume below the limiting height
Fire Alarm and Signaling Systems
7 key facts
Water-Based Fire Protection Systems
7 key facts
Special Hazard Systems
7 key facts
Passive and Structural Fire Protection
7 key facts
Human Behavior and Evacuation
7 key facts
Free with an account

Read the complete PE Fire Protection study notes for “Fire Protection Analysis”

Our first full set of comprehensive notes, about 15 minutes of reading: Performance-based design · Fire risk assessment · Fire models · Energy storage systems, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

1. Fire Protection Analysis

10-15 of 85 questions from April 2027. Covers performance-based design and fire risk assessment, fire models, and energy storage systems (prevention and protection, characteristics, test reports).

Key facts

  • Performance-based process: define scope, set goals and objectives, set performance criteria, develop scenarios, develop trial designs, evaluate them and document the result.
  • Risk combines frequency and consequence. Multiply along event tree branches, and use AND/OR gates in fault trees.
  • Failure mode analysis asks how each component can fail, what the effect is and how it will be detected.
  • Zone models divide a room into a hot upper layer and a cool lower layer. CFD resolves the space into many cells at much higher computing cost.
  • Zone models lose accuracy in long corridors, very tall spaces and complex geometry, where uniform layers do not form.
  • UL 9540A tests at four levels: cell, module, unit and installation. The current edition builds large-scale fire testing into the installation level.
  • NFPA 855 covers installation of stationary energy storage systems, including siting, protection and hazard mitigation analysis.

Flashcards

Probability along an event tree branchMultiply the branch probabilities.
UL 9540A level for unit-to-unit propagationUnit level.
Key zone model assumptionTwo uniform layers per room.
UL 9540A level for gas composition from thermal runawayCell level.

Exam tip: State the model's assumptions before accepting its output. Exam questions often ask whether a model is valid for a space.

2. Fire Science

10-15 of 85 questions. Covers heat transfer (conduction, convection, radiation), fire chemistry (combustion reactions, thermophysical properties) and fire dynamics (growth, size, fuel load, enclosure fires).

Key facts

  • Conduction: q'' = k dT/dx. Convection: q'' = h dT. Radiation: q'' = emissivity x sigma x T^4, with sigma = 5.67 x 10^-8 W/m^2 K^4 and T absolute.
  • t-squared fires: slow 0.00293, medium 0.01172, fast 0.0469 and ultrafast 0.1876 kW/s^2.
  • Point source radiation: q'' = (radiative fraction x Q) / (4 pi R^2).
  • Heat release from oxygen consumption is about 13.1 MJ per kg of oxygen for most fuels.
  • Heskestad mean flame height: L = 0.235 Q^(2/5) - 1.02 D, with Q in kW and D in m.
  • Le Chatelier's rule estimates mixture LFL: 1/LFL = sum of (y_i / LFL_i), with y as the fuel-only volume fraction.
  • Flashover commonly corresponds to about 20 kW/m^2 at floor level and 500-600 C in the upper layer.

Flashcards

Fast t-squared growth coefficient0.0469 kW/s^2.
Stefan-Boltzmann constant5.67 x 10^-8 W/m^2 K^4.
Heat released per kg of oxygen consumedAbout 13.1 MJ.
Medium t-squared growth coefficient0.01172 kW/s^2.

Exam tip: Convert temperature to kelvin before using any radiation equation. A Celsius value there is always wrong.

3. Smoke Control Systems

6-9 of 85 questions. Covers basis of design (system types, components, criteria), calculations (plumes, venting, pressure, exhaust), and inspection, testing and commissioning, with NFPA 92 supplied.

Key facts

  • Axisymmetric plume above the limiting height: m = 0.071 Qc^(1/3) z^(5/3) + 0.0018 Qc (kg/s, kW, m).
  • Limiting flame height: z_l = 0.166 Qc^(2/5). Below it, m = 0.032 Qc^(3/5) z.
  • Use convective heat release in plume equations, commonly 0.7 of total.
  • Pressurization uses pressure differences across smoke barriers; opening force at doors limits the maximum.
  • Exhaust design must watch for plugholing, where inlets draw in air from below the smoke layer.
  • Makeup air velocity must stay low near the plume so that it does not disturb the plume or smoke layer.
  • Commissioning verifies each mode, sequence, pressure and flow, and periodic testing keeps systems working.

Flashcards

Axisymmetric plume above limiting heightm = 0.071 Qc^(1/3) z^(5/3) + 0.0018 Qc.
Limiting flame heightz_l = 0.166 Qc^(2/5).
Failure where an exhaust inlet draws air from under the layerPlugholing.
Plume below the limiting heightm = 0.032 Qc^(3/5) z.

Exam tip: Check z against the limiting flame height before you choose an equation. It takes seconds and prevents a wrong branch.

Test yourself on these topics

Take the free 15-question PE Fire Protection test, then save your results to unlock your Readiness Score and the mistakes bank.

Start the free test

4. Fire Alarm and Signaling Systems

8-12 of 85 questions. Covers system selection, design criteria (device location, interfaces, sequence of operations), principal components, and calculations (voltage drop, battery, notification, detector response), with NFPA 72 supplied.

Key facts

  • Standby battery: 24 hours of standby plus 5 minutes of alarm, or 15 minutes for in-building voice evacuation, with a 20% safety margin.
  • Voltage drop on a two-wire circuit uses 2 x I x R x L.
5 more key facts, 8 key notes, 100 flashcards and 375 practice questions for this topic are in premium.

Flashcards

Standby and alarm period for non-voice systems24 hours standby, then 5 minutes of alarm.

Exam tip: Write the conductor count into every voltage drop calculation, since forgetting the return path doubles your answer.

5. Water-Based Fire Protection Systems

12-18 of 85 questions, the largest area. Covers system selection, design criteria (water supply, densities, pressure, design areas, hose stream), principal components, and calculations (hydraulics, equipment sizing, supports), with NFPA 13 and NFPA 20 supplied.

Key facts

  • Sprinkler flow: Q = K p^0.5, with Q in gpm and p in psi.
  • Hazen-Williams friction loss: p = 4.52 Q^1.85 / (C^1.85 d^4.87) in psi per foot.
5 more key facts, 7 key notes, 100 flashcards and 375 practice questions for this topic are in premium.

Flashcards

Sprinkler discharge equationQ = K p^0.5.

Exam tip: Use the 0.54 exponent to solve for flow and the 1.85 exponent to solve for pressure. Mixing them is a classic error.

6. Special Hazard Systems

7-11 of 85 questions. Covers system selection (CO2, inert gas, clean agent, chemical, foam, oxygen reduction, ignitable liquid drainage floors), design criteria, components, and calculations (LFL, concentrations, flow rates). NFPA 11, 30, 400 and 2001 are supplied.

Key facts

  • Halocarbon agent weight: W = (V/s) x C/(100 - C), with s the specific vapor volume at the design temperature.
  • Inert gas agents use a different relationship: X = 2.303 (Vs/s) log10(100/(100 - C)) x V, based on free efflux.
5 more key facts, 7 key notes, 100 flashcards and 375 practice questions for this topic are in premium.

Flashcards

Halocarbon agent weight equationW = (V/s) x C/(100 - C).

Exam tip: Check whether the agent calculation is halocarbon or inert before you start, because the equations differ.

7. Passive and Structural Fire Protection

8-12 of 85 questions. Covers building materials (fire resistance rating, testing, material assessment), geometry and compartmentation, structural fire protection (equivalency, alternate approaches, structural fire analysis, char) and opening protection (dampers, doors, firestopping).

Key facts

  • ASTM E119 and UL 263 set standard fire exposure and acceptance criteria for assemblies.
  • Steel temperature limits in standard tests are about 538 C average for columns and 593 C average for beams.
5 more key facts, 7 key notes, 100 flashcards and 375 practice questions for this topic are in premium.

Flashcards

W/D meaningWeight per foot over heated perimeter.

Exam tip: Remember direction: a lighter section needs more protection. If your new thickness falls when W/D falls, recheck the ratio.

8. Human Behavior and Evacuation

9-14 of 85 questions. Covers prescriptive egress and life safety design, performance-based egress concepts (evacuation time, scenarios, occupant density) and psychological and physiological response to fire (tenability, decision making), with NFPA 101 supplied.

Key facts

  • Assembly without fixed seats: 7 ft^2 net per person concentrated, 15 ft^2 net less concentrated.
  • Capacity factors are commonly 0.2 in. per person for level components and ramps and 0.3 in. per person for stairs.
5 more key facts, 7 key notes, 100 flashcards and 375 practice questions for this topic are in premium.

Flashcards

Concentrated assembly occupant load factor7 ft^2 net per person.

Exam tip: Separate required egress capacity from timed egress. Code capacity can be met while a timed analysis still shows a problem.

How to pass

  • 85 questions in 8.5 hours is 6 minutes each, but searching supplied PDFs takes time. Practice in the searchable PDFs rather than in printed books.
  • The supplied standards are searchable PDFs with linked chapters, so learn which chapter holds each topic before exam day.
  • Use the current standards list. NFPA 12 and NFPA 25 have dropped off it, NFPA 855 has been added and every other listed edition has changed.
  • Book your Pearson seat as soon as your board approves you, because there is only one sitting per year.

Frequently asked questions

How long should I study for the PE Fire Protection exam?

Most working candidates need 4 to 8 weeks at 45 to 60 minutes a day. Book your exam once your Readiness Score has stayed at 80 or higher for about a week.

Can I take the PE Fire Protection exam online?

NFPA delivers this exam at Prometric in-person computer-based test centers; it is not offered as a remote exam on NFPA's current pages. Format: closed book with electronic references: the PE Fire Protection Reference Handbook and, where a question needs them, NFPA 11, 13, 20, 30, 72, 92, 101, 400, 855 and 2001, all supplied on screen. Personal copies are not allowed. Questions use both SI and US customary units. The real exam has multiple-choice questions and alternative item types; this prep uses 4-option single-best-answer questions. Check the NFPA Certification Candidate Handbook for the rules.

What score do I need to pass the PE Fire Protection exam?

Not published by NCEES. Results are reported as pass or fail. The exam has 85 questions and a time limit of 9.5-hour appointment: 2-minute nondisclosure agreement, 8-minute tutorial, 8.5 hours of exam and a 50-minute scheduled break.

What are the most tested topics?

The outline covers fire protection analysis, fire science, smoke control systems, fire alarm and signaling systems, water-based fire protection systems, special hazard systems, passive and structural fire protection, human behavior and evacuation. Use the free practice test to see which ones you need most.

The premium PE Fire Protection study path

Premium PE Fire Protection prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 85 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 8 topics

Your step-by-step study path

  1. 1
    Fire Protection Analysis8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Notes free with an account
  2. 2
    Fire Science8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  3. 3
    Smoke Control Systems8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  4. 4
    Fire Alarm and Signaling Systems8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  5. 5
    Water-Based Fire Protection Systems7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  6. 6
    Special Hazard Systems7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  7. 7
    Passive and Structural Fire Protection7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  8. 8
    Human Behavior and Evacuation7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  9. Final step: 6 full mock exams85 questions each, timed like test day. Pass them, then book your exam.
    Premium

Get every note, flashcard and question

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a single code book, for a certification employers and AHJs ask for by name
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One NFPA exam of your choice: CFPS, CFI or CFPE
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: formulas and values sheet, code values quick reference, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

Summarized from NFPA's official candidate information and the rules cited, checked November 2026. Confirm current requirements with National Council of Examiners for Engineering and Surveying (NCEES), with approval by your state licensing board.